새 페이지 1
새 페이지 1
" DAIHAN" : Water Purification System,
Ultra Pure System, 전자동 초순수 제조장치,18.3
㏁ |
■
제
품 안 내
■
제조국
/ 제조사 |
■
Korea
/ 대한과학 |
■
상품명 |
■
초순수
제조장치 ( Ultra Pure System ) |
■
짧은
소개 |
■ UP
water Analyzing Data
1) Metal Impurity (Unit : ppb)
2) Anion/Cation(unit/ppb) |
■
제
품 특 징 (
Features )
*
* UP(Ultra Pure) System
초순수를 생산.
* Certified ISO 9001(NO :
K-920)
* 16×2 Characters Backlight Digital Display
* Very simple to exchange the Filter-Pack(Molding Type)
* U.P Water : A.A.S , HPLC , I.C , ICP , G/C/MS , Tissue Culture, etc
- General laboratory tests.
- Preparation of stock solution-washing & Rinsing of
glassware
* Water Quality Display : Digital Display U.P : 0 to 18.3MΩ-cm
* Display : 16×2 Characters Backlight LCD Digital-display
* Controller : Microprocessor One Touch Technology
* Controller Functions :
1. Self Test : Self testing for diagnosing operating
2. Auto Recycling : Auto recycling at 2nd Alert message
3. Manual Recycling : Enable to recycle for maintain RO Pure
4. Time Elapse indicator : Cusor blinking
5. Built-in ROM, RAM, CPU Microprocessor
6. Filter Exchange Indicator : Programmable by steps as below
1) 1st Alert Message : Warning message for the
filter exchange
2) 2nd Alert Message : Exchange Filter
* Safety Functions :
1. Low Pressure of Tap Water : Auto/Manual Operating Modes
2. Automatic Motor Stop Functions :
1) Low Pressure
2) Tank Full.
3) Suspension of Tap Water Supply
|
3. 초순수 제조장치 (
Ultra Pure System )
P.NIX UP System
• Certified ISO 9001 (NO : K-920)
• Obtained GD, QD Mark(Good Design, Qualified Design)
• Awarded the Korean Excellent Products
• Awarded "Top 100 excellent patented products"
• Built-in RS 232C Port
• Built-in Volumetric dispensing function by timer.
• Automatic regular recirculation to maintain the optium um water
quality level.
• Programming by 2 steps for the filter & UV lamp
exchanges to maintain water quality |
■
Applications
Type |
Scholar |
Scholar-UV |
Bio |
Integrate |
TypeⅠgrade
water |
● |
● |
● |
● |
Analytical
Instruments |
● |
● |
● |
● |
AAS, ICP/MS, IC |
● |
● |
|
● |
HPLC, GC, TOC |
|
● |
|
● |
Organic
analysis |
|
● |
|
● |
Cell &
tissue cultuer |
|
|
● |
● |
In vitro
fertilization |
|
|
● |
● |
Electrophoresis |
|
|
● |
● |
R Nase, D Nase
& DNA free |
|
|
|
● |
Molecular
Biology |
|
|
|
● |
※ Applicable Model : P.NIX Power, UP/Human
Power, UP/Nex Power, UP Series
■ 규격
(Specifications)
구
분 |
P.NIX UP900
|
Water Quality Display |
UP product : UP to 18.3㏁-㎝, Feed water : 0 to 100㎲/cm,
Temperature : 0 to 100℃
|
Controller |
Microprocess one Touch technology
|
Display |
16 x 2 Characters Backlight LCD Digital Display
|
Type |
Scholar |
Scholar-UV |
Bio |
Integrate |
Feature |
|
|
|
|
- 0.2㎲/cm
Final filter |
STD |
STD |
STD |
STD |
- 254/185 UV
lamp |
|
STD |
|
STD |
- MW 5000 UF
filter |
|
|
STD |
STD |
- Dispenser |
STD |
STD |
STD |
STD |
- PVDF ¼Dispensing
gun |
|
|
|
|
Included
Filters & Accessories |
Post
A/C filter, P.NIX UP Pack, Manual, Power cord. |
Water Quality |
|
- Product
flower rate(L/min) |
1.2 |
1.2 |
1.0 |
1.0 |
- TOC(ppb) |
5 - 10 |
0 - 5 |
5 - 10 |
0 - 5 |
- Endotoxin(Eu/㎖) |
NA |
NA |
< 0.001 |
< 0.001 |
- Bacteria(cfu/㎖) |
< 1 |
< 1 |
< 1 |
< 1 |
- Particles(>0.22㎲/㎖) |
< 1 |
< 1 |
< 1 |
< 1 |
Controller
Functions |
1. Self Test : Self-Test
for external & internal system operationg conditions. |
2. Auto recirculation
function: |
① Regular
recycling at every setting time |
② Automatic
recycling when the product value is less stetting value |
③ Automatic
recycling when the system produess lower value of UP water than setting
value. |
3. Volumetric dispensing :
After setting of timer, the quantitative water production is abailable. |
4. Auto sensor Calibration
: Automatic compensating function to maintain the sensor accuracy. |
5. Filler exchange
indicator (Programmable by 2 steps) |
① 1st alert
messange : 1st reminder for Pack exchange |
② 2nd alert
messange : Filter Pack must be exchanged. |
6. UV lamp exchange
indicator : At the accurate time for UV lamp exchange, the exchange
message will be displayed |
7. Auto monitoring for feed
water quality : When the purity and temperature of feed water are
exceeding the setting value, the system will be stopped automatically. |
8. Built-in RS 232C Port :
Various application, maintenance and print are available by interface to
PC. |
Safety function |
1. Feed water quality
monitoring : Check for the purity of feed water |
2. Feed water
temp monitoring |
3. UV lamp
monitoring |
UP water analyzing data |
Fe |
Cu |
Al |
Ni |
Zn |
Cr |
Na |
K |
|
Cl- |
NO2 |
NO3 |
SO4 |
(ppb)
|
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
|
<0.005 |
<0.005 |
<0.005 |
<0.005 |
|
Optional accessories |
Software |
Dimensions
(W x D x H) |
295×500×465mm
|
Power |
220V/230V, 50/60Hz, 60W
|
Human UP System
• Certified CE
• Certified ISO 9001(NO: K-920)
• Obtained GD, QD Mark(Good Design, Qualified Design)
• Awarded "Top 100 excellent patented products" by Korean
Patent Office/Hankook daily newspaper.
• Awarded the Korean Excellent Products
• 16 x 2 Characters Backlight Dightal Display.
• Automatic Recycling at 2nd setting value.
• Manual Recycling function for maintain Ultra Pure Water
• Very simple to exchange the Filter-Pack.(Molding Type) |
■
Applications
Type |
Scholar |
Scholar-UV |
Bio |
Integrate |
TypeⅠgrade
water |
● |
● |
● |
● |
Analytical
Instruments |
● |
● |
● |
● |
AAS, ICP/MS, IC |
● |
● |
|
● |
HPLC, GC, TOC |
|
● |
|
● |
Organic
analysis |
|
● |
|
● |
Cell &
tissue cultuer |
|
|
● |
● |
In vitro
fertilization |
|
|
● |
● |
Electrophoresis |
|
|
● |
● |
R Nase, D Nase
& DNA free |
|
|
|
● |
Molecular
Biology |
|
|
|
● |
※ Applicable Model : P.NIX Power, UP/Human
Power, UP/Nex Power, UP Series
■ 규격
(Specifications)
구
분 |
Human UP900
|
Water Quality
Display |
0 to 18.3㏁-㎝
|
Product water
quality |
Up to 18.3㏁-㎝
|
Controller |
Microprocess
one Touch technology |
Display |
16 x 2 Characters Backlight LCD Digital Display
|
Type |
Scholar |
Scholar-UV |
Bio |
Integrate |
Feature |
|
|
|
|
- 0.2㎲/cm
Final filter |
STD |
STD |
STD |
STD |
- 254/185 UV
lamp |
|
STD |
|
STD |
- MW 5000 UF
filter |
|
|
STD |
STD |
- PVDF ¼Dispensing
gun |
|
Included
Filters & Accessories |
Post
A/C filter , Human UP Pack , Manual ,Power cord. |
Water Quality |
|
|
|
|
- Product
flower rate(L/min) |
1.2 |
1.2 |
1.0 |
1.0 |
- TOC(ppb) |
5 - 10 |
0 - 5 |
5 - 10 |
0 - 5 |
- Endotoxin(Eu/㎖) |
NA |
NA |
< 0.001 |
< 0.001 |
- Bacteria(cfu/㎖) |
< 1 |
< 1 |
< 1 |
< 1 |
- Particles(>0.22㎲/㎖) |
< 1 |
< 1 |
< 1 |
< 1 |
Controller
Functions |
1. Self Test :
Self-test for diagnosing operating conditions.(Internal/External) |
2. Auto
cleaning : auto drain for 30sec, when it turns ON(power ON) |
3. Auto
flushing : for the membrane washing, automatically. |
-
Flushing time : 1 to 99min. |
-
Period cycle : 1 to 99hrs. |
4. Manual
flushing : Manually washing the filters is available |
5. Time elapse
indicator : cursor blinking |
6. Built-in
ROM, RAM, CPU(one chip) microprocessor. |
7. Filler
exchange indicator : programmable by 2 step as below ; |
①1st
alert messange : 1st reminder for filter exchange |
②
2nd alert messange : The filter must be exchanged |
UP water
analyzing data |
1>metal impurity (unit
: ppb) |
2>anion/cation (unit :
ppb) |
Fe |
Cu |
Al |
Ni |
Zn |
Cr |
Na |
K |
|
Cl- |
NO2 |
NO3 |
SO4 |
(ppb)
|
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
|
<0.005 |
<0.005 |
<0.005 |
<0.005 |
|
|
Dimensions
(W x D x H) |
400×567×500mm |
Power |
220V, 50/60Hz, 60W
|
NEX UP System
• Certified ISO 9001 (NO : K-920)
• ASTM TypeⅠ grade water
• Ultra pure water quality : < 18.3㏁-㎝
• Very simple to exchange the Filter-Pack. |
■
Applications
Type |
Scholar |
Scholar-UV |
Bio |
Integrate |
TypeⅠgrade
water |
● |
● |
● |
● |
Analytical
Instruments |
● |
● |
● |
● |
AAS, ICP/MS, IC |
● |
● |
|
● |
HPLC, GC, TOC |
|
● |
|
● |
Organic
analysis |
|
● |
|
● |
Cell &
tissue cultuer |
|
|
● |
● |
In vitro
fertilization |
|
|
● |
● |
Electrophoresis |
|
|
● |
● |
R Nase, D Nase
& DNA free |
|
|
|
● |
Molecular
Biology |
|
|
|
● |
※ Applicable Model : P.NIX Power, UP/Human
Power, UP/Nex Power, UP Series
■ 규격
(Specifications)
구
분 |
Nex UP 1000
|
Water quality
display |
Up
to 18.3㏁-㎝ |
Display |
LED digital display
|
Type |
Scholar |
Scholar-UV |
Bio |
Integrate |
Feature |
|
|
|
|
- 0.2㎲/cm
Final filter |
STD |
STD |
STD |
STD |
- 254/185 UV
lamp |
|
STD |
|
STD |
- MW 5000 UF
filter |
|
|
STD |
STD |
- PVDF ¼Dispensing
gun |
|
|
|
|
Included
Filters & Accessories |
Post
A/C filter , Human UP Pack , Manual , Power cord. |
Water Quality |
|
|
|
|
- Product
flower rate(L/min) |
1.2 |
1.2 |
1.0 |
1.0 |
- TOC(ppb) |
5 - 10 |
0 - 5 |
5 - 10 |
0 - 5 |
- Endotoxin(Eu/㎖) |
NA |
NA |
< 0.001 |
< 0.001 |
- Bacteria(cfu/㎖) |
< 1 |
< 1 |
< 1 |
< 1 |
- Particles(>0.22㎲/㎖) |
< 1 |
< 1 |
< 1 |
< 1 |
Safety
function |
Recirculation
function
_ To maintain optimum quality and inhibit microbial growth |
UP water
analyzing data |
1>metal impurity (unit
: ppb) |
2>Anion/cation (unit :
ppb) |
Fe |
Cu |
Al |
Ni |
Zn |
Cr |
Na |
K |
|
Cl |
NO2 |
NO3 |
SO4 |
(ppb)
|
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
<0.005 |
|
<0.005 |
<0.005 |
<0.005 |
<0.005 |
|
|
Filter pack
(one touch molding pack) |
Very simple to
exchange the one-touch molding filter-pack |
STD accessories |
①A/C filter,
Human UP Pack
②Manual, Power cord |
Optional
accessories |
PVDF ¼Dispensing gun
|
Dimensions
(W x D x H) |
400×638×500mm
|
Power |
220V, 50/60Hz, 100W
|
■
가격 (
Price [VAT포함]
)
CAT
No. |
Description |
단위
/
갯수 |
Price
[VAT포함] |
가격문의 |
|